Korelin, A.A., Trufanova, N.M. The Effect of Technological Parameters on the Quality of Cross-Linked Insulation of Medium- and High-Voltage Cables. Russ. Electr. Engin. 96, 916–920 (2025). https://doi.org/10.3103/S1068371225701275 Russian Electrical Engineering, 2025, Vol. 96, No. 11, pp. 916–920. Abstract—The main factors that affect the degree of cross linking of peroxide cross-linked polyethylene insulation in medium- and high-voltage cables have been considered. The vulcanization properties necessary to calculate the degree of cross linking have been determined by a rotational rheometer study. Based on the axisymmetric mathematical model of peroxide cross linking in the ANSYS Fluent package, the temperature dependences have been obtained to calculate the final degree of insulation cross linking. The influence of geometric dimensions of the insulated core, as well as of other process parameters, such as line speed and temperature, on the quality of the resulting insulation has been determined. Conclusions regarding the significant and minor factors that affect the quality of highvoltage cable products have been drawn. Keywords: power cables, polyethylene insulation, peroxide cross linking, degree of cross linking, continuous vulcanization DOI: 10.3103/S1068371225701275 ISSN 1068-3712, Russian Electrical Engineering, 2025, Vol. 96, No. 11, pp. 916–920. © Allerton Press, Inc., 2025. Russian Text © The Author(s), 2025, published in Elektrotekhnika, 2025, No. 11, pp. 22–26. A. A. Korelina, * and N. M. Trufanovaa a Perm National Research Polytechnic University, Perm, 614990 Russia *e-mail: korelin-art@yandex.ru Received August 25, 2025; revised September 17, 2025; accepted September 18, 2025